Displaying Space-Borrowing Information. Click the Total borrowed space link from either the Group Disk Space panel or the Pool Disk Space panel. You can also see these statistics through several CLI commands. Refer to the Dell EqualLogic Group Manager CLI Reference Guide for more information. How to Replace a Dell EqualLogic Controller. Follow safety and/or ESD protocols. Make sure the faulty controller is the SECONDARY controller. If not, you must fail over the array (see below). With faulted controller in the secondary position, disconnect all of the cables (noting their location). Remove the controller by operating latches.
I have a Dell Equallogic San and it is being accessed by many VMWare hosts (Esxi v5.1). Today morning I could find an error like
iSCSI login to target ' ' failed for the following reason:Initiator disconnected from target during login
But Just after 10 seconds this error disappeared and now login works fine.
I have checked this particular datastore through VCenter Server, but I was unlucky to find any errors logged there. Can anyone please tell me what is the basic reason for this error and how it can be solved permanently?
![Money Money](/uploads/1/2/5/7/125783997/117395632.jpg)
VysakhVysakh
1 Answer
If this is something that seems to be recurring, you should ensure that your VMware hosts are configured according to Dell's best practices recommendations.
The most likely cause would be the iSCSI login timeout value (defaults to 5 seconds, recommended 60 seconds).
See kb.vmware.com/kb/2007829 for more info
JimNimJimNim